On this page
To judge an FRM® logistic regression classifier, start with the decisions it makes at a stated probability threshold, then count correct alarms, false alarms, missed events and correct rejections. Accuracy alone can flatter a model when defaults are rare. Precision, recall and the false positive rate expose different errors; an ROC curve and its area summarise ranking across thresholds.
Why predicted probabilities need a decision rule
Logistic regression estimates the probability of a binary event, such as default versus no default. A business rule turns that probability into a flag: scores at or above a chosen threshold are positive, and scores below it are negative. Changing that threshold can change the reported performance even when the fitted model and its underlying scores have not changed. Always ask which threshold produced a quoted confusion matrix.
This is distinct from deciding whether to fit linear or logistic regression. The existing FRM model choice explanation addresses the type of outcome being predicted. Here the question comes later: given a logistic model, does its pattern of alarms fit the decision? GARP places quantitative analysis in Part I and offers learning objectives to guide study; its FRM study materials are the authority for current exam preparation.
Build the four cells before calculating anything
Imagine a loan portfolio whose actual outcomes are now known. A true positive is an actual default that the model flagged. A false negative is an actual default that it missed. A false positive is a borrower who did not default but was flagged; a true negative is a nondefault that was left unflagged. The word positive refers to the event being sought, not to a desirable credit outcome.
There are two independent ways to check the matrix. True positives plus false negatives must equal all actual defaults. False positives plus true negatives must equal all actual nondefaults. Separately, true positives plus false positives must equal all flags, while false negatives plus true negatives must equal all nonflags. These row and column totals are especially useful when a question supplies several counts indirectly. The Federal Reserve's classification study sets out the matrix and these metric denominators in a fraud-detection setting; the loan counts here are a separate invented teaching example.
A worked loan example with invented numbers
The following figures are invented solely to show the method; they describe no lender, portfolio or observed model. Suppose an analyst tests 200 loans. Twenty later default and 180 do not. At one threshold the model flags 30 loans, of which 15 actually default. The 15 flagged defaults are true positives. The remaining 15 flags are false positives. Five actual defaults were not flagged, leaving 165 true negatives.
Check every total before judging the model: 15 true positives plus five false negatives gives the 20 defaults; 15 false positives plus 165 true negatives gives the 180 nondefaults. Thirty flags are split equally between genuine and false alarms. One hundred and seventy loans were unflagged, of which five nevertheless defaulted. A reader who starts from the flag total rather than the actual default total can easily swap precision and recall.
Accuracy is the share of all loans correctly classified: 15 plus 165, divided by 200, or 90%. Its complement, the error rate, is 15 plus five, divided by 200, or 10%. Both use the entire test set. These figures are arithmetically sound, yet they give little insight into whether the default alarm is useful. The event occurs in only one tenth of this invented sample.
Precision asks whether a flag is worth attention. It divides the 15 true positives by all 30 predicted positives, giving 50%. Recall asks how much of the actual default population was caught. It divides 15 by 20 actual positives, giving 75%. Thus half the investigations would be false alarms in this toy example, while one quarter of defaults would be missed. Neither fraction alone says which decision is best.
The F1 score combines precision and recall as their harmonic mean. With precision of 0.50 and recall of 0.75, twice their product divided by their sum is 0.60. Its value falls sharply if either component is weak. It can be a compact comparison when the two concerns deserve roughly comparable attention, but it does not encode the actual cost of an investigation or a missed default.
Why a high accuracy headline can mislead
Use the same invented 200 loans as a deliberately simple benchmark. A rule that predicts no default for everyone gets all 180 nondefaults right and every default wrong. Its accuracy is also 90%, exactly equal to the model's reported accuracy. Yet its recall is zero because it finds none of the twenty defaults. The comparison reveals information hidden by the overall accuracy figure, without claiming that the example model is deployable.
An imbalanced sample makes this trap common. When the positive event is scarce, true negatives can dominate the accuracy numerator. A classifier may therefore improve the operational decision while barely changing accuracy, or post impressive accuracy while missing the cases of interest. Compare the classifier with a relevant simple benchmark and inspect both error types. Do not call the higher accuracy model better until the decision's costs are stated.
Choose a threshold by the cost of each mistake
Lowering a threshold generally increases the number of flagged loans. It can catch additional defaults, increasing recall, but it can also create more false alarms. Raising the threshold usually does the reverse. Precision does not change mechanically in a fixed direction at every small threshold step: it depends on the labels of the particular observations newly added or removed. The familiar trade-off is a tendency, not a guaranteed law for every sample.
Suppose a limited review team can examine only a small number of flags. Precision matters because wasted reviews displace other cases. If a missed default creates the more serious loss, recall becomes prominent. Those priorities may conflict; the correct threshold depends on the intended action and the relative consequences, not a universal exam-safe percentage. A candidate should state the decision context before recommending one metric.
The false positive rate conditions on actual nondefaults, not on flags. In the worked example it is 15 divided by 180, about 8.3%. This rate answers how often a nondefault is mistakenly flagged. It differs from one minus precision, which conditions on all predicted positives. This distinction matters when comparing how broadly a model disturbs the nondefault population with how trustworthy each positive alert is.
Read the ROC curve and AUC carefully
The receiver operating characteristic curve plots recall, also called the true positive rate, against the false positive rate for many thresholds. Each point represents a different rule applied to the same model scores. A point nearer the upper left combines more caught positives with fewer false alarms. The curve is useful when the choice of threshold has not yet been fixed, because it displays how both rates change across possible operating points.
Area under the ROC curve, or AUC, is a summary of ranking: a higher value generally means positive cases tend to receive higher scores than negative cases. An area of one half corresponds to chance-like ranking; an area of one represents perfect separation in the evaluated sample. AUC does not specify the threshold a review team should use, the quality of predicted probability calibration, or the cost of taking action.
ROC curves also deserve care when positives are rare. The false positive rate may look modest because its denominator contains many actual negatives, while the absolute number of false alarms can still overwhelm an investigation queue. For that reason, return to the confusion matrix and precision at the contemplated threshold. A threshold-free ranking score and a threshold-specific operating result answer related but different questions.
An exam answer that stays anchored to the decision
When given a table, first write the actual-positive and predicted-positive totals, then identify the four cells. Compute accuracy only after checking that the cells sum to the sample size. Next compute precision from flagged cases and recall from actual event cases. If an ROC question follows, make clear that its horizontal axis is the false positive rate, not the false discovery share among flags.
A concise interpretation should say what the numbers mean in words. In the invented example, the model catches three quarters of eventual defaults but half its alerts are false. That is more informative than calling it 90% accurate. Whether the trade-off is acceptable remains a policy and resource question. The FRM programme page gives the broader study context; the methodology page explains the academy's approach to learning and review.
Finally, separate evaluation from estimation. Performance measured on the same loans used to fit a model can overstate how well it will work on fresh cases. If the question describes a holdout set, keep its counts separate from training counts. If it does not, avoid claiming out-of-sample predictive strength. The companion discussion of overfitting and the validation gap addresses that separate problem.
Sources
- FRM Learning Objectives | GARP · garp.org · Retrieved
- FRM Study Materials | GARP · garp.org · Retrieved
- CardSim: A Bayesian Simulator for Payment Card Fraud Detection Research | Federal Reserve · federalreserve.gov · Retrieved
- Out-of-Sample Performance of Recession Probability Models | Federal Reserve · federalreserve.gov · Retrieved